Toplotne pumpe
Fujitsu toplotna pumpa WSYK160DG9 / WOYK160LCTA 16KW
- Specifikacija
- Dimenzija
| Capacity range | 16kW | ||
| +7°C / +35°C floor heating | Heating capacity | 15.17kW | |
| Input power | 3.70kW | ||
| COP | 4.10 | ||
| +2°C / +35°C floor heating | Heating capacity | 13.50kW | |
| Input power | 4.34kW | ||
| COP | 3.11 | ||
| -7°C / +35°C floor heating | Heating capacity | 13.50kW | |
| Input power | 5.40kW | ||
| COP | 2.50 | ||
| +7°C / +45°C radiators | Heating capacity | 13.00kW | |
| Input power | 4.00kW | ||
| COP | 3.25 | ||
| -7°C / +45°C radiators | Heating capacity | 13.00kW | |
| Input power | 6.37kW | ||
| COP | 2.04 | ||
| Backup heater | Capacity | 9.0kW×pcs.(3.0×3pcs) | |
| Hydraulic unit | Model name | WSYK160DG9 | |
| Power source | 3Φ 400V, 50Hz | ||
| Water circulation | Rated | 43.8L/min | |
| Min / Max | 27.45 / 54.8L/min | ||
| Dimensions H×W×D | 800 × 450 × 457mm | ||
| Weight (Net) | 42kg | ||
| Buffer tank capacity | 16L | ||
| Expansion vessel capacity | 8L | ||
| Leaving water temperature range | 8 ~ 60°C | ||
| Water pipe connection diameter | Flow / Return | Φ25.4 / Φ25.4mm | |
| Space heating characteristics | |||
| Temperature application | °C | 55 | |
| Energy efficency class | A+ | ||
| Rated heat output (Prated) | kW | 13 | |
| Seasonal space heating energy efficiency (ns) | % | 117 | |
| Annual energy consumption | kWh | 9062 | |
| Sound power level | Hydraulic indoor unit | dB(A) | 46 |
| Outdoor unit | 71 | ||
| Outdoor unit | Model name | WOYK160LCTA | |
| Power source | 3Φ 400V, 50Hz | ||
| Current | Rated | 5.5A | |
| Max | 10.5A | ||
| Noise level (Sound pressure) | 56dB(A) | ||
| Dimensions H×W×D | 1290 × 900 × 330mm | ||
| Weight (Net) | 92kg | ||
| Refrigerant | R410A | ||
| Refrigerant amount | 2.50kg | ||
| Additional refrigerant charge amount | 50g/m | ||
| Connection pipe | Diameter | Liquid | Φ9.52mm |
| Gas | Φ15.88mm | ||
| Length | Min / Max | 5 / 20m | |
| Length (chargeless) | Max | 15m | |
| Height difference | Max | 15m | |
| Operation range | Heating | -25 ~ 35°C | |
| Space heating characteristics | |||
| Temperature application | °C | 35 | |
| Energy efficency class | A+ | ||
| Rated heat output (Prated) | kW | 14 | |
| Seasonal space heating energy efficiency (ns) | % | 149 | |
| Annual energy consumption | kWh | 7408 | |
| Sound power level | Hydraulic indoor unit | dB(A) | 46 |
| Outdoor unit | 71 | ||
Instagram: